Power Transformer (PM)

Electrical transformer inspection service, electrical transformer maintenance, checking electrical transformer condition, changing transformer oil

Inspect single-phase transformers, three-phase transformers, provide maintenance services for all types of Core Type, Shell Type, with certification reports and recommendations for safe use.

PM Transformers Checklist

Scope of support

SERVICE
CLEAN
CHECK
Wipe, vacuum, and clean the transformer by wiping it with white alcohol to return it to its original condition.
Change the silica gel desiccant and check the color of the silica gel desiccant (Conservator Tank Type)
NO
Check transformer oil, filter transformer oil, change transformer oil to meet standards.
NO
NO
Check the insulation value of the coil (Insulation Testing)
Check the insulation value of the oil according to the manufacturer’s standards.
Clean the area around the transformer installation site.
Check the connection points and tighten the connections on both high and low voltage sides (Connection Tightening), clean the heat sink and clean the transformer yard.
PM REPORT
THAI
ENGLISH
Issue 1 PM report with certification signed by an electrical engineer.
NO

In the chart above, the green check mark indicates the scope of our work at no additional cost. Different check marks may have certain conditions. Customers can contact the agent before purchasing or using the service.

Transformer maintenance

  • Extend the life of the transformer
  • Prevent damage to the transformer while supplying load
  • Know the actual load while using the transformer
  • Prevent the transformer from exploding
  • Save on repair costs or buying a new one
  • Prevent ground leakage and sudden power outages
  • The transformer can work at full efficiency

18 Checklists to Check if Your Transformer is in Safe Operating Condition

Insulation Resistance Measurement

Insulation resistance test to check the tendency of insulation deterioration in transformers. The test procedure involves short-circuiting each set of windings of the transformer together.

Service by a professional team with international standards

Check and replace the silica gel desiccant.

If the desiccant deteriorates, the color will fade and turn black. It should be replaced to ensure the most effective moisture collection.

Transformer oil leakage

Oil leakage from transformer due to deteriorated or damaged rubber seals should be replaced (Bushing Low Voltage) by an expert urgently.

Check carefully

  • Check for rust, corrosion, and damage to the transformer.
  • Check for damaged honing, bending, or misalignment.
  • Check for worn or damaged frame gaskets, thick dust that may cause electrical leakage to the ground or extinguishing.
  • Check for low oil level in the transformer spare oil tank, add oil.
  • Check for dirty or leaking cooling fins.
  • Check for high- and low-voltage cable connectors at the bushings.

Approved for Certification

Official license of a legal entity authorized to provide inspection and certification services for machinery, cranes, boilers.

Council of Engineers

Professional Engineer, Legal Entity Type, from the Engineering Council

Department of Welfare

Licensed legal entity authorized for machinery, crane, and boiler inspection and certification.

Support / ContactTel : (065) 441 9324

เพิ่มเพื่อน