Electrical Thermal Imaging Service with Infrared Camera

THERMO SCAN INSPECTION SERVICE

No need to shut down the power supply, the electrical system inspection by thermal imaging camera can be carried out while the production process is still running and when an abnormality is detected, it allows for efficient maintenance planning to fix the problem at the source, saving customers money.

Anomalies are detected and maintenance plans can be planned effectively.

What are the advantages of THERMO SCAN?

Advantages of THERMO SCAN
CHECK
It is a proactive protection against electrical equipment failure
Prevent sudden power failures that may cause the production process to stop (Break down)
Save costs and plan to solve problems more accurately and precisely.
Able to plan maintenance and improve efficiency of electrical systems and electrical equipment.
Plan to manage heat accumulation problems in electrical control cabinets
Prevent explosions or short circuits and prevent fires caused by electrical systems.

In the chart above, the green check mark indicates the scope of our work at no additional cost. Different check marks may have certain conditions. Customers can contact the staff before purchasing or using the service.

Engineer thermal analysis thermo scan
The electrical ground wire is hot.

Factors that interfere with electrical system inspection using thermal imaging cameras

In addition to the expertise of the inspector and the adjustment of parameters in the camera or analysis program, there are also other external factors that may cause errors in electrical system inspection using a thermal imaging camera. For example, excessive humidity or inspection of electrical systems during short periods of rain, wind speed in the inspection area, distance between the object being inspected and the location of the thermal imaging camera being inspected, and inspection of electrical systems in areas with high electromagnetic field strength. Therefore, parameter adjustment and inspection at the right time, in the right area and at the right location have a great impact on the accuracy of electrical system inspection using a thermal imaging camera.

International Electrical Testing Association (NETA) standards

It is recommended that immediate action be taken to correct a hot spot when the temperature difference (ΔT) between the hot spot and other spots operating in the same manner and under similar load conditions is greater than 15°C, or when the ΔT between the electrical components experiencing the problem is greater than 30°C above the ambient air temperature.

Thermo-scan electrical systems with ISO 9001-certified engineers using calibrated, ISO 17025-compliant equipment for precise, standardized results.

Some sample images of our services with leading customers nationwide

Central Department Store Co., Ltd. or Central Department Store

Approved for Certification

Official license of a legal entity authorized to provide inspection and certification services for machinery, cranes, boilers.

Council of Engineers

Professional Engineer, Legal Entity Type, from the Engineering Council

Department of Welfare

Licensed legal entity authorized for machinery, crane, and boiler inspection and certification.

Support / ContactTel : (065) 441 9324

เพิ่มเพื่อน